| The
system is supplied with two hoses. The longer 5/8" diameter suction
hose is supplied with female garden hose fittings on each end. One end
of this hose attaches to the pump and the other end is designed to screw
onto the collar surrounding the top of the dip tube. The shorter
discharge hose has a female garden hose fitting on one end, which is
designed to attach to the pump and a
1/2"
female SAE flare fitting on the other end, which is designed to fit
inside a waste container.
Priming
the system:
Before
initial use, either pour or suck a small amount of oil into the pump and
lines. By filling the pump head with oil, the impeller is protected from
running dry and shortening its life. Once the pump is filled with oil,
this procedure does not have to be repeated for subsequent uses. The
fixture at the top of the base plate is designed to store the oil-filled
hoses after use.
The
system can withdraw oil via the dip tube or through smaller nylon tubes
which are inserted into the dip tube and down into the oil pan. Reverso
has a wand set- the OP-610-3 which includes:
a
1/4" nylon tube, a 5/16" nylon tube and a 7/16" hose for
insertion over the dip tube with an external clamp.
Electrical
Connection:
The
system is supplied with clamps for connection to the battery terminals.
The red handled clamp is designed to be attached to the Positive (+)
terminal, while the black handled clamp is designed to be attached to
the Negative (-) terminal. With the wiring connections made in this
manner, the pump will operate in the same direction as indicated by the
arrow on the pump label.